Remove curved tube (A11691-00)

and locknut (A11318-00) to ensure proper

grooves are filled with dielectric grease

before cable installation (see Figures 16

or 49). Remove and clean any excess

grease after assembly.

NOTE

HIGH VOLTAGE

CONNECTIONS FOR

SHIELDED/NON-METALLIC

CORE CABLE - A10560-XX

Figure 19: Atomizer Removal

High Voltage Connection -

Cascade End

Insert end of cable (end of cable with the green

grounding wire attached) thru compression nut

of output tube of RansPak

cascade (74793-01

or 74793-02) until it bottoms into banana jack re-

ceptacle. Tighten compression nut by hand, then

tighten 1/2 turn more with a wrench.

DO NOT

over-tighten as this may damage cable.

Secure green wire with yellow stripe (attached

to high voltage cable) to any known good earth

ground, such as a water pipe, etc., using the at-

tached ring terminal.

FILL THIS CAVITY

WITH DIELECTRIC GREASE

DO NOT FILL CENTER CAVITY

WITH DIELECTRIC GREASE

> Arcing/fire hazard exists if ungrounded

metal connections (air or fluid) are used in

the spray area. Use plastic nonconductive

connections, or ensure metal connections

are at ground potential.

W A R N I N G

!

RMA-303 Indirect Charge - Maintenance

Ransburg

52

LN-9252-06.4

Advertising