Ransburg – Ransburg RMA Indirect A11600 User Manual
Page 63
![background image](/manuals/348104/63/background.png)
Figure 38: Tubing Removal
Figure 37: Fiber Optic Installation/Removal
Figure 39: Break-Away Ring
Separating Atomizer Body From
Atomizer Extension (Applicator off
Robot)
(See Figures 37, 38, and 39)
Removal
Remove the mounting ring by first removing the
break-away ring. Loosen the six (6) screws that
hold the break-away ring to the rear plate as-
sembly (see Figure 39). The break-away ring
and the mounting ring will now come off.
Loosen the fiber optic assembly in the rear plate
by loosening the set screw with a 3/32" hex key
(see Figure 37). Pull the fiber optic cable from
its hole in the solvent manifold and rear plate as-
sembly. Leave end loose in atomizer extension.
Loosen and remove the cup wash line from the
manifold by unscrewing the 1/4-inch fitting with a
3/16" end-wrench from the solvent manifold and
leave loose in the atomizer extension.
Figure 36: Cup Wash Manifold Removal
Figure 35: Cup Wash Manifold Removal / Re-
placement
RMA-303 Indirect Charge - Maintenance
Ransburg
59
LN-9252-06.4