9english setup instructions – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 11

Advertising
background image

Model 17800B / 17801B Recovery/Recycling/Recharging Unit

9

ENGLISH

Setup Instructions

The.50.lb.(23kg).unit.tank.must.be.filled.with.refrigerant.before.the.unit.is.ready.

for.use.

TANK FILL

. 1.. Connect.the.96".blue.low-side.hose.to.the.liquid.valve.fitting.on.the.source.

tank..If.using.R-134a,.you.may.need.the.1/2".acme.to.low-side.adapter.

included.in.the.accessory.kit.

. Note: Some tanks have slightly different valve configurations. Be sure to

connect the blue hose to the LIQUID valve. This valve may be red on some

tanks and blue on others.

. 2.. Press.

SHIFT/RESET and.ENTER.at.the.same.time;.then.press.2..The.unit.

will.begin.transferring.refrigerant.from.the.source.tank.to.the.unit.tank.

. 3.. The.unit.will.fill.the.recovery.tank.with.up.to.30.lbs.of.refrigerant.and.

automatically.stop..The.display.will.flash.“CPL”.when.the.process.is.

complete.

WARNING: To prevent personal injury,

Wear safety goggles when working with refrigerant.
Use only authorized refillable refrigerant tanks.
Disconnect hoses using extreme caution!
All hoses may contain refrigerant under pressure.
Read and follow all warnings at the beginning of this

manual before operating the unit.