Func, 35 english, Operating guidelines – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 37

Advertising
background image

Model 17800B/17801B Recovery/Recycling/Recharging Unit

35

ENGLISH

USING THE DIAGNOSTIC MODE

The diagnostic mode allows you to run individual components or retrieve stored

information. To access the diagnostic mode, press and hold

SHIFT/RESET and

then press

ENTER. The display will show the message “FUNC.” To exit the

diagnostic mode, press

SHIFT/RESET again.

Some diagnostic functions exit the diagnostic mode when completed, so to

continue with more diagnostic functions you must re-enter the diagnostic mode.

Once in the diagnostic mode you can do the following:

Initial Vacuum Mode:

1. Press

1 to enter initial vacuum mode. The display will show the message

“VACUUM.” The use of this mode is described in the initial setup

instructions in this manual.

2. Press

HOLD/CONT to stop the pump.

Set Display for Pounds or Kilograms:

1. Press “0” to display the unit of measure currently set (the unit assumes you

want to change the setting).

2. Press

ENTER to toggle between “lb” and “kg”.

3. When the desired setting displays, press

SHIFT/RESET to save the

selection.

Display Total Weight of Recovered Refrigerant:

1. Press “3” to display the total amount of refrigerant recovered by the unit

since the last filter-drier change.

2. This counter resets with every filter-drier change.