16 english operating instructions – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 18

Advertising
background image

© Bosch Automotive Service Solutions LLC

16

ENGLISH

Operating Instructions

CHARGING PROCEDURES

WARNING:

Wear safety goggles when working with refrigerant. Use only

authorized refillable refrigerant tanks. Disconnect hoses using

extreme caution!
All hoses may contain refrigerant under pressure. Read and

follow all warnings at the beginning of this manual before

operating the unit.

The.unit.will.display.the.message.“CHECK.REFRIGERANT”.if.there.are.less.than.

six.(6).pounds.of.refrigerant.in.the.tank..The.charging.system.will.not.function.if.

this.message.is.displayed..If.you.try.to.charge.in.this.situation,.the.display.will.also.

show.“Add.HOLD”.to.let.you.know.that.refrigerant.needs.to.be.added.to.the.tank..
Add.more.refrigerant.to.the.tank.than.what.is.needed.for.charging.(see.Adding

Refrigerant to the Tank)..To.check.the.weight.of.refrigerant.in.the.tank,.press.and.

hold.

SHIFT/RESET,.then.press.ENTER to.access.the.diagnostic.mode..Press.“7”.

to.display.the.weight.of.refrigerant.in.the.tank..Press.

SHIFT/RESET.again.to.exit.

the.diagnostic.mode.
Follow.the.A/C-R.system.manufacturer’s.instructions.regarding.specific.recharging.

specifications..You.must.replace.any.oil.lost.from.the.A/C-R.system.during.

recovery.with.new.oil..Dispose.of.waste.oil.in.an.appropriate.manner.

. 1.. Open.the.high-side.valve.and,.if.allowable,.the.low-side.valve.on.the.unit’s.

control.panel.

. 2.. Press.

SHIFT/RESET.until.the.message.“CHG”.appears.on.the.display.

. 3.. Press.

CHG and.enter.the.weight.of.the.refrigerant.to.be.charged.

. 4.. Press.

ENTER..The.display.will.flash.to.indicate.that.the.charge.amount.has.

been.recorded.in.the.unit’s.memory.

. 5.. Press.

CHG again.to.begin.the.charging.process.

. 6.. The.display.will.show.the.message.“AUTOMATIC”.and.the.amount.

programmed.for.recharging..The.display.counts.down.to.zero.as.charging.

proceeds.

. 7.. When.charging.is.complete,.the.display.shows.the.message.“CPL.”

HOLD

CHECK REFRIGERANT

Add

LBS

CHARGE

PROGRAM

2.75

LBS

CHARGE

2.75

AUTOMATIC

VACUUM

PROGRAM

MINUTES

CPL

Weight Example*

Weight Example*

*Enter the correct

weight for your ap-

plication.