Model 17800B / 17801B Recovery/Recycling/Recharging Unit

19

ENGLISH

.

7.. Transfer.stops.automatically.and.the.display.shows.the.“CPL”.message.

when.the.source.tank.is.empty.and.has.been.pulled.to.a.partial.vacuum.or the.

weight.of.refrigerant.in.the.unit.tank.reaches.37.pounds..The.display.toggles.

between.“CPL”.and.the.weight.in.the.tank.

.This.process.takes.about.45.minutes..You.can.interrupt.it.at.any.time.by.pressing.

HOLD/CONT.once..Press.HOLD/CONT.again.to.resume.operation,.or.press.

SHIFT/RESET.to.end.the.process..The.transfer.of.new.refrigerant.is.limited.by.

weight.to.leave.space.(about.6.pounds.of.refrigerant).in.the.unit.tank.for.recovery.

purposes..

. 8..

When using R-12,.close.the.supply.valve.on.the.source.tank.(when.using.

a.disposable.tank,.turn.it.right.side.up.first)..Carefully disconnect.the.96.inch.

(244-cm).blue.low-side.hose.from.the.6-inch.(15.2-cm).yellow.adapter,.and.

then.remove.the.yellow.adapter.from.the.source.tank.

When using R-134a, close.the.supply.valve.on.the.source.tank,.(when.

using.a.disposable.tank,.turn.it.right.side.up.first)..Carefully disconnect.the.

96.inch.(244-cm).blue.low-side.hose.from.the.low-side.connector.port.

adapter.and.then.remove.the.adapter.from.the.source.tank..

. 9.. Press.

RECOVER..The.hose.will.be.pulled.into.a.partial.vacuum.and.the.unit.

will.turn.off.automatically..If.the.hose.is.partially.clear,.the.unit.will.display.

“CH-P.”.Press

HOLD/CONT.to.finish.clearing.the.hose..Close.the.low-side.

manifold.valve.

.10....Connect.the.96-inch.(244-cm).red.high-side.hose.to.the.unit’s.high-side.port..

You.can.also.attach.an.oil.injector.to.the.unit’s.low-side.port..Oil.injectors.

will.not.connect.to.the.wrong.ports..The.R-12.oil.injector.has.a.1/4.inch.flare.

connector;.the.R-134a.oil.injector.has.a.1/2.inch.Acme.connector.

Any non-condensable gases in the tank can be removed during the recycling

sequence. Your unit is now ready for use.

Operating Instructions

NOTE:

Close both tank

valves when

the unit is not in

use. Inspect the

unit periodically

for leaks. The

manufacturer

of the recovery/

recycling

unit does not

reimburse for

lost refrigerant.

* The display shows the weight of

refrigerant added to the tank.

LBS

KG

CHECK REFRIGERANT

2.40

HOLD

OIL(OUNCES)

CPL

Weight Example*

Func

CHECK REFRIGERANT

Add

a

a

Advertising