Diagram of Control Panel

RECOVERY PROCEDURES

WARNING:

Wear safety goggles when working with refrigerant. Use only

authorized refillable refrigerant tanks. Disconnect hoses using

extreme caution!
All hoses may contain refrigerant under pressure. Read and

follow all warnings at the beginning of this manual before

operating the unit.

Before.beginning.recovery,.verify.the.unit.is.set.up.as.described.in.the.Setup

Instructions..Also.verify.there.is.vacuum.pump.oil.in.the.vacuum.pump.

. 1.. Connect.the.high-.and.low-side.hoses.to.the.A/C-R.system,.as.you.would.

normally.connect.your.manifold.gauge.set.

. 2.. Verify.both.the.high-.and.low-side.valves.on.the.control.panel.are.open..Also.

verify.both.valves.on.the.tank.are.open.

. 3.. Plug.the.unit.into.a.correct.voltage.outlet,.and.turn.on.the.

MAIN POWER.

switch..The.display.shows.either.“134a”.(which.indicates.R-134a.automotive.

refrigerant.that.uses.

1

/

2

".Acme..fittings).or.“R12”.(which.indicates.all.other.

refrigerant.types.that.use.

1

/

4

".flare.fittings)..The.display.may.flash.“door,”.

which.indicates.the.unit.is.cleared.and.can.be.set.up.for.any.refrigerant.type.

. 4.. Press.

RECOVER.

Low Side Gauge

High Side Gauge

High Side Valve

Liquid/Vapor Indicator

Display

Main Power Switch

Air

Purge

Valve

Keypad

Low Side Valve

Tank Pressure Gauge

INST0919

Unit Circuit Breaker

(17800B only)

System

Oil

Indicator

Oil-less

Compressor

Protector

Tank

Temperature

Gauge

Advertising