CAUTION:

When setting

up for new

types of

refrigerant,

a clearing

process must

be performed.

ADDING REFRIGERANT TO THE TANK

CAUTION:

R-134a systems have special fittings (per SAE

specifications) to avoid cross-contamination with other refrigerant

systems. Read and follow all warnings given at the beginning of this

manual.

NOTE: .Purchase only tanks of R-134a refrigerant that have 1/2 inch (1.2cm)

Acme threads. This is necessary to match the hose adapter.

.....1..Connect.the.96-inch.(244.cm).blue.low-side.hose.to.the.unit's.low-side.port.

NOTE:.Disposable tanks have only one valve and most must be turned upside

down to transfer liquid. If you are using a disposable tank, follow the instructions

on the side of the tank to obtain a liquid supply.

. 2..

When using R-12,.connect.the.6-inch.(15.2-cm).yellow.adapter.to.the.

source.tank.liquid.valve.first..Then.connect.the.96-inch.(244-cm).blue.low-

side.hose.to.the.adapter.

When using R-134a,.connect.the.low-side.connector.port.adapter.to.the.

source.tank.liquid.valve.first..Then.connect.the.blue.96-inch.(244-cm).low-

side.hose.directly.to.the.adapter.

. 3.. Open.the.LIQUID.valve.on.the.source.tank..(There.is.only.one.valve.on.a.

non-refillable.tank.)

. 4.. Close.the.high-side.manifold.valve,.and.open.the.low-side.manifold.valve.on.

the.front.panel.of.the.unit..Open.both.valves.on.the.unit.tank.

. 5....Press.

SHIFT/RESET.and.ENTER.at.the.same.time.to.access.the.diagnostic.

mode..The.display.shows.the.message.“FUNC.”

6.. Press

2.to.begin.transferring.refrigerant..The.display.shows.the.“Add”.

message.for.about.two.seconds,.then.shows.the.amount.of.refrigerant.

transferred.