I5.00, 23 english, Maintenance procedures – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 25

Advertising
background image

Model 17800B/17801B Recovery/Recycling/Recharging Unit

23

ENGLISH

CHANGING THE VACUUM PUMP OIL

When the vacuum pump has run for a total of 10 hours, the “OIL” message will

flash on the display to signal that an oil change is needed. To change the vacuum

pump oil, follow these steps:
1. Turn on the

MAIN POWER switch. The display shows the selected

refrigerant type.

2. Press

SHIFT/RESET and the message “PROGRAM VACUUM MINUTES

15:00” displays.

3. Press

VACUUM. The display shows the “OIL” message.

4. Remove the door access screws from the right side of the unit. Open the door.

5. Remove the black plastic plug on the oil fill port.
6. Remove the oil drain cap from the vacuum pump, then drain the contaminated

oil into a suitable container. (Dispose of it according to local, state, and

federal regulations). Replace the oil drain cap.

7. Attach the flexible spout and cap to the oil bottle, and pour approximately six

(6) ounces of vacuum pump oil into the oil fill port.

8. Verify the manifold valves are closed, then press

SHIFT/RESET and

ENTER at the same time to reset the ten-hour timer.

9. Press

VACUUM. While the pump is running, slowly add new vacuum pump

oil until the oil level is even with the line on the reservoir’s sight glass.

10. Replace the black plastic plug on the oil fill port.

Diagram of Vacuum Pump Components

Oil Filler Tube

Inlet

Sight Glass

Oil Fill Port

Pump Exhaust

Oil Drain Fitting

Maintenance Procedures

VACUUM

PROGRAM

MINUTES

I5.00

HOLD

VACUUM

OIL