Cl-c, 12 english operating instructions, Caution – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 14

Advertising
background image

© Bosch Automotive Service Solutions LLC

12

ENGLISH

Operating Instructions

CAUTION:

Before changing

refrigerant

types,

disconnect the

red high-side

and blue low-

side hoses from

the A/C system.

CHANGING REFRIGERANT TYPES

. 1.. Verify.the.red.high-side.and.blue.low-side.hoses.are.disconnected.from.the.

A/C.system,.then.open.the.manifold.and.tank.valves.

. 2.. Press.and.release.

SHIFT/RESET until the “Clr” message appears.

. 3.. Press.

HOLD/CONT.to.start.the.system.oil.separator.clearing.process.

. . During.the.system.oil.separator.clearing.process,.the.compressor.is.activated.

and.the.“OIL”.message.displays..The.compressor.will.stop.while.the.unit.

equalizes.pressure.and.the.“OIL”.message.will.continue.to.display..When.the.

unit.reaches.the.correct.pressure,.the.display.alternately.flashes.the.messages.

“OIL”.and.“drn.”.Open.the.system.oil.drain.valve.to.drain.the.oil..After.all.oil.

has.drained,.close.the.oil.drain.valve..The.message.changes.to.“Cont.”..Press.

any.key.to.complete.the.oil.separator.clearing.process..When.compressor.

stops.again,.the.message.changes.to.“CL-c.”

NOTE:

Perform

“RECOVERY

PROCEDURES”

before starting

“CHANGING

REFRIGERANT

TYPES.”

Diagram of Unit’s Components — External View

INST0916

AUTOMATIC

VACUUM

OIL

HOLD

CL-c

High Side Port

Low Side Port

Lockout Door

Blue Liquid Hose

Red Vapor Hose

Tank Liquid Valve

Tank Vapor Valve

Air Purge Fitting

50 lb. (23 kg)

Unit Tank

Scale Assembly

Air Purge Hose