Full, 15 english, Operating instructions – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 17: Caution

Advertising
background image

Model 17800B / 17801B Recovery/Recycling/Recharging Unit

15

ENGLISH

RECYCLING PROCEDURES

WARNING:

Wear safety goggles when working with refrigerant. Use only

authorized refillable refrigerant tanks. Disconnect hoses using

extreme caution!
All hoses may contain refrigerant under pressure. Read and

follow all warnings at the beginning of this manual before

operating the unit.

. 1.. Verify.both.valves.on.the.tank.are.open..

. 2.. Press.and.hold.

SHIFT/RESET,.then.press.“1”.to.start.the.recycling.process.

. . If.the.recovery.tank.is.full,.the.display.will.show.the.message.“FULL.”.Press.

HOLD/CONT.to.resume.operation.

. 3.. After.about.five.(5).minutes.of.recycling,.the.tank.temperature.should.

equalize..You.can.then.purge.non-condensables.

. 4.. To.purge.non-condensables,.check.the.tank.temperature.gauge.to.find.the.

temperature.of.the.refrigerant..Use.that.temperature.to.find.the.correct.

pressure.for.that.refrigerant.on.the.pressure/temperature.chart.on.the.top.of.

the.unit..Compare.the.pressure.from.the.chart.to.the.pressure.shown.on.the.

tank.pressure.gauge..If.the.gauge.pressure.exceeds.the.target.pressure.by.more.

than.10.psi,.open.the.air.purge.valve.on.the.control.panel.for.about.30.seconds.

to.release.non-condensables.from.the.tank..Then.close.the.air.purge.valve.

and.allow.the.tank.to.stabilize.for.about.30.seconds..Check.the.tank.pressure.

gauge.again..Repeat.this.step.as.necessary.during.the.recycling.procedure.

. . Note:.The.tank.temperature.display.can.show.Fahrenheit.or.Celsius.degrees..

Refer.to.Changing the Temperature Scale.in.this.manual.

. 5.. To.stop.recycling,.close.the.tank’s.LIQUID.valve..The.unit.will.pull.into.a.

vacuum.and.shut.off.automatically..Press.any.key.to.exit.recycle.mode.

CAUTION:

You can stop

recycling

instantly by

pressing HOLD/

CONT, then

SHIFT/RESET,

but this can leave

liquid refrigerant

in the low side of

the unit. Closing

the tank’s LIQUID

valve is the

recommended

method.

Operating Instructions

HOLD

AUTOMATIC

RECYCLE

FULL

Advertising
This manual is related to the following products: