CHECKING FOR LEAKS

Every three months, or as often as required by local or state laws, check the unit

for leaks. As with any mechanical equipment, general use, moving the unit, and

vibration can cause fittings to loosen.

1. Turn off the

MAIN POWER switch, and disconnect the power cord from the

outlet.

2. Remove the door access screws from the right side of the unit. Open the door.

3. Use a leak detector to probe all fitting connections for refrigerant leaks.

Tighten fittings if a leak is indicated.

4. Close the door and replace the door access screws.

NOTE:

Inspect the unit

periodically

for leaks. The

manufacturer

does not

reimburse for

lost refrigerant.

Maintenance Procedures

CHANGING THE TEMPERATURE SCALE—

FAHRENHEIT OR CELSIUS

The temperature scale is set at the factory. Use the following steps to toggle the

temperature scale between Fahrenheit and Celsius.

1. Turn off the

MAIN POWER switch, and disconnect the power cord from the

outlet.

2. Remove the four screws that secure the top section of the unit's protective cov-

ering, and remove the covering.

3. Locate the selector switch on the back of the tank temperature display.

4. Change the position of the switch to change the temperature scale.

5. Replace the top section of the unit's protective covering, and replace the four

screws that secure the covering.

Temperature Selector

Switch