A/C-R SYSTEM EVACUATION

WARNING:

Wear safety goggles when working with refrigerant. Use only

authorized refillable refrigerant tanks. Disconnect hoses using

extreme caution!
All hoses may contain refrigerant under pressure. Read and

follow all warnings at the beginning of this manual before

operating the unit.

. 1.. Verify.the.high-.and.low-side.hoses.are.connected.to.the.A/C-R..

system,.and.that.the.high-.and.low-side.valves.are.open.

. 2.. Press.

SHIFT/RESET.to.toggle.the.display.to.show.“PROGRAM.VACUUM.

MINUTES.15.00.”.Fifteen.minutes.is.the.default.time.for.evacuation..To.

change.the.time,.press.the.appropriate.keys.to.display.the.desired.time..Then.

press.

ENTER.

The longest time that can be programmed is 98.99 (98 minutes and 99

seconds).

. 3.. Press.

VACUUM to.start.evacuation..The.display.counts.down.the.time.

remaining..If.the.message.“U-HI”.appears,.you.have.25.psi.or.greater.of.

pressure.at.the.inlet..You.must.recover.that.pressure.to.continue..If.necessary,.

press.

RECOVER.

. 4.. When.the.programmed.time.has.expired,.the.vacuum.pump.automatically.

shuts.off.and.the.display.shows.“CPL.”.Press.any.key.to.exit.vacuum.mode.

. . To.run.the.vacuum.pump.continuously,.program.the.time.to.“99.00,”.press.

ENTER,.then.press.VACUUM..The.pump.will.start.and.the.display.will.

show.“CON.AUTOMATIC.VACUUM.”.To.turn.the.vacuum.pump.off,.press.

HOLD/CONT.