This overview is designed as a quick reference when using your unit. Read and

follow all warnings in the operating manual.

RECOVERY OVERVIEW

1. Connect the high- and low-side hoses to the A/C-R system.

2. Check the manifold gauges. There must be pressure to recover refrigerant.

3. Verify both the high- and low-side valves on the control panel are open. Also

verify both valves on the tank are open.

4. Plug the unit into a correct voltage outlet, then turn on the

MAIN POWER

switch.

5. Press

RECOVER:

• If there is pressure in the unit, the self-clearing process starts.

• If there is no internal pressure, refrigerant recovery begins.

• The unit then shows “RECOVER AUTOMATIC” and the weight of

refrigerant being recovered into the tank.

6. Once the recovery and/or self-clearing procedure is complete, the compressor

shuts off automatically. The display will flash “CPL” and the weight of

refrigerant recovered.

7. If the A/C-R system pressure rises above zero, press

HOLD/CONT to

recover the remaining refrigerant.

8. The display also shows “OIL (OUNCES).” This is a reminder to drain the

system oil separator into a suitable container by opening the ball valve on the

side of the unit.

You must replace any oil lost from the A/C-R system during recovery with

new oil. Dispose of waste oil in an appropriate manner.

Operating Overview

Weight Example

VACUUM

PROGRAM

MINUTES

CPL

AUTOMATIC

LBS

RECOVER

7.95

FLASHES

a a