44 english, Troubleshooting – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 46

Advertising
background image

© Bosch Automotive Service Solutions LLC

44

ENGLISH

Runs but will not shut off

Problem: Oil drain valve is open.

Solution: Close the oil drain valve.

Problem: There is a leak in the A/C-R system.

Solution: Locate and repair all system leaks.

Problem: Hoses are not connected to the vehicle.

Solution: Check hose connections.

Problem: Oil return solenoid is open.

Solution: Replace the oil return solenoid.

RECYCLING OPERATION

Compressor does not start, or stops prematurely

Problem: Power cord is not plugged in, or there is no power at plug.

Solution: Check circuit for power.

Problem: Tank valves are closed.

Solution: Open both valves, and verify hoses are connected to the tank.

Problem: “CH-F” message on digital display.

Solution: Remove and replace the filter-drier (see Replacing the Filter-Drier),

and pull a vacuum before continuing.

Refrigerant does not flow

Problem: Refrigerant supply empty or low.

Solution: Add refrigerant to the tank.

Problem: Tank valves are closed.

Solution: Open both valves, and verify hoses are connected to the tank and

the unit.