28 english, Maintenance procedures – Robinair 17801B Recovery, Recycling, Recharging Unit User Manual

Page 30

Advertising
background image

© Bosch Automotive Service Solutions LLC

28

ENGLISH

12. To check scale accuracy, follow the Correct Weight Verification procedure.

WARNING

Unplug the unit before beginning service work. Incorrect use or
connections can cause electrical shock. Only qualified personnel
should perform service work.

If scale assembly and UL circuit are not calibrated, scale can overfill
the tank, causing possible explosion and/or vehicle overcharge.

UL CIRCUIT CALIBRATION

NOTE: Always calibrate the scale first. Then remove the (4) screws that hold down

the keypad on the control panel before attempting to calibrate the UL circuit.

1. Remove all weight from the scale platform.

2. Turn on the

MAIN POWER.

NOTE: If the unit is just being turned on, the screen will default to display the

selected refrigerant type.

3. Press

SHIFT/RESET until “PROGRAM” displays.

4. When the “PROGRAM” message displays, press

SHIFT/RESET and ENTER

at the same time. The “FUNC” message displays.

5. Press

6.

NOTE: Any weight on the scale when 6 is pressed will not be shown on the display.

The unit automatically zeros the weight on the scale when

6 is pressed. If you re-

move the weight, the display will show the change in total weight, but will not show

a negative sign.

6. Place a known weight of EXACTLY 75 lbs. on the scale platform. The dis-

play will show “75 lb. ± .04 lbs/.02kg.”

7. Adjust the potentiometer (P1 POT) set screw just until the “HOLD” message

displays. (The potentiometer adjusting screw is located on the circuit board.)

Maintenance Procedures

NOTE:

You must have

a known weight

of 75 lb. ± .01

(34.02 kg ±.005).