CHARGING OVERVIEW

Follow the manufacturer’s recommendation for charging. You must replace any oil

lost from the A/C-R system during recovery with new oil. Dispose of waste oil in

an appropriate manner.

1. Open the high-side valve and, if allowable, the low-side valve.

2. Press

CHG and enter the weight of the refrigerant to be charged.

3. Press

ENTER, then press CHG again. The display counts down to zero, then

shows the “CPL” message when complete.

4. Close the high- and low-side valves and start the A/C-R system. Compare the

gauge readings to the manufacturer’s specifications.

5. Turn off the A/C-R system and disconnect the high-side hose from it.

6. Start the A/C-R system and open both manifold valves to pull refrigerant from

the hoses.

7. At the lowest recommended operating pressure, close the low-side valve and

turn off the A/C-R system. Disconnect the low-side hose.

8. Close both manifold valves and turn off the

MAIN POWER switch.

Operating Overview

Weight Example*

*Enter the correct weight for your application.

LBS

CHARGE

PROGRAM

2.75

AUTOMATIC

LBS

CHARGE

CL-L

VACUUM

PROGRAM

MINUTES

CPL