7. If the scale does not read the weight accurately, recalibrate the scale and

UL circuit using the following instructions. If the scale does not respond to

testing, verify the scale cable is plugged into the main circuit board.

8. Press

SHIFT/RESET to exit this mode

CALIBRATING THE SCALE

NOTE: The scale assembly and UL circuit MUST be calibrated when installing

a replacement scale assembly or circuit board. To ensure continued charging

accuracy, periodically confirm the checklist below.

1. Remove all weight from the scale platform.

2. Turn on the

MAIN POWER switch.

NOTE: If the unit is just being turned on, the screen will default to display the

selected refrigerant type.

3. Press

SHIFT/RESET and ENTER until “PROGRAM” displays.

4. When the “PROGRAM” message displays, press

SHIFT/ RESET at the

same time. The “FUNC” message displays.

5. Press

9. The display is blank.

6. Press

RECOVER and ENTER at the same time.

7. The DATE message flashes, then “0.00” displays. Enter the current month and

year. For example, if the unit is being calibrated on November 8th, 1998, enter

1,1,9,8 and then press ENTER.

8. The “CAL” message will flash, then the “ZERO” message displays.

9. Verify nothing is on or touching the scale platform, then press

ENTER.

10. The “CAL” message will flash, then the “A1” message displays.

11. Place a certified weight (between 20 and 70 lbs.) in the center of the scale

platform. Enter the weight from the display. For example, to record 20 lbs.

on the scale, press “

2,0,0,0” on the keypad, then press ENTER. The display

returns to the vacuum mode.

Maintenance Procedures