2. Specifications

2.

Specifications

(1)

Maximum Speed

The maximum speed for the actuator is limited due to the resonance of the ball screw axis and the limitation
of the number of motor rotation.
Make sure that the maximum speed of your actuator does not exceed the applicable limit specified in the
table below.

[Standard]

Restriction in Stroke and Maximum Speed (unit: mm/s)

Type

Motor Type

Lead

(mm)

Stroke (mm)

25

50

75

100

RCP-RA2C

20P

1

25

Restriction in Stroke and Maximum Speed (unit: mm/s)

Type

Motor Type

Lead

(mm)

Stroke (mm)

50

100

150

200

250

300

RCP2-RA3C

28P

2.5

114

-

-

5

187

-

-

RCP2-RA4C

42P

2.5

125<114>

118<114>

87

5

250

237

175

10

458

350

RCP2-RA6C

56P

4

130

8

210

16

450<400>

RCP2-RA8C

60P

5

150

10

300

RCP2-RA10C

86P

2.5

63

5

125

10

250<167>

(Note) Values in brackets < > are the maximum speed when

vertically oriented.