5. Installation

When mounting the unit in the horizontal orientation using the tapped holes on the back surface, have a

support base as shown in the figure below.

Support base

Caution: When mounting the unit with using the datum surface and the back surface, pay attention

so the external force is not applied to the main body. The body or the attachment part on
the back may get damaged.

(7)

Tightening bolts

Install the actuator using Unichro hexagon socket head bolts of strength category 10.9 or higher.

Mounting bolt

Tightening torque

In the case that steel is used for

the seating surface

In the case that aluminum is used

for the seating surface

M3

154N·cm (15.8kgf·cm)

83N·cm (8.47kgf·cm)

M4

359N·cm (36.7kgf·cm)

176N·cm (18.0kgf·cm)

M6

1234N·cm (126kgf·cm)

536N·cm (54.7kgf·cm)

M8

2997N·cm (306kgf·cm)

1148N·cm (117kgf·cm)

M10

5937N·cm (606kgf·cm)