12. Process for Motor Replacement

3)

Untighten the hex socket head cap screw (M3 × 5)

using a 1.5mm sized hex wrench.

(Note) Do not forget to turn off the power to the

controller in case you have moved the rod

with using the controller.

4)

Pull the rod further.

In the range of lead length, you will find the second

hex socket head cap screw (M3 × 5) tightening the

motor coupling.

For low lead actuators, it is difficult to move the rod

manually. Do not intend to move it forcefully, connect

the controller and move it with JOG operation.

5)

Untighten the hex socket head cap screw (M3 × 5)

using a 1.5mm sized hex wrench.

(Note) Do not forget to turn off the power to the

controller in case you have moved the rod

with using the controller.

Advertising