12. Process for Motor Replacement

19) Untighten the hex socket head cap screw (M3 × 5)

using a 1.5mm sized hex wrench.

Tightening Torque : 85N·cm (8.7kgf·cm)

(Note) Do not forget to turn off the power to the

controller in case you have moved the rod

with using the controller.

20) Untighten the hex socket head cap screw (M6 × 6)

on the top of the actuator using a 3mm sized hex

wrench.