IAI America RCP2W-RA10C User Manual

Page 30

Advertising
background image

24

2. Specifications

[With double guides]

Restriction in Stroke and Maximum Speed (unit: mm/s)

Type

Motor Type

Lead

(mm)

Stroke (mm)

50

100

150

200

250

300

RCP2-RGD3C

28P

2.5

114<93>

-

-

5

187

-

-

RCP2-RGD4C

42P

2.5

125<114>

118<114>

87

5

250

237

175

10

458

350

RCP2-RGD6C

56P

4

130

8

210

16

450<400>

(Note) Values in brackets < > are the maximum speed when

vertically oriented.

[Splash proof type]

Restriction in Stroke and Maximum Speed (unit: mm/s)

Type

Motor Type

Lead

(mm)

Stroke (mm)

50

100

150

200

250

300

RCP2W-RA4C

42P

2.5

125<115>

115

85

5

190

175

10

450<250>

350<250>

RCP2W-RA6C

56P

4

100

8

200

16

320<265>

RCP2W-RA10C

86P

2.5

63

5

125

10

250<167>

(Note) Values in brackets < > are the maximum speed when

vertically oriented.

Caution: Please do not set the speed or acceleration/deceleration settings beyond the rated values.

It may cause an occurrence of vibration, malfunction, or shorten the product life.
When having the actuator run to synchronize with multiple axes, adjust the speed setting
of the axis with the maximum speed and the acceleration/deceleration of the axis with the
minimum acceleration/deceleration.
Setting especially the acceleration/deceleration beyond the rated values may cause a creep
or a slip of the coupling.