DJSP
app.SDA2.JitterMeasure.Parameters.Djsp
Djsp is Dj calculated from Spectral jitter decomposition, according to the Dual Dirac model. SDA2 displays this value
as DJ when app.SDA2.JitterMeasure.Parameters.JitterModel is set to Dual-Dirac Spectral.
ClearSweeps
Action
Clear any accumulated result data. Useful for example to restart an average, or parameter statistics.
Description
View
Bool
Sets/Queries the trace's 'Viewed' state. When true, the trace is displayed on one of the display
graticules. Note that even when a trace is not visible, it may be used as a source for Math, Measure,
etc.
Description
ClearSweeps
Action
View
Bool
RESULT
app.SDA2.JitterMeasure.Parameters.Djsp.Out.Result
ISI
app.SDA2.JitterMeasure.Parameters.ISI
This value is Inter-Symbol Interference, one of the components of DDJ. The SDA2 computes this value directly from
the waveform, independent of the setting of app.SDA2.JitterMeasure.Parameters.JitterModel. ISI and DCD
constitute DDj.
ClearSweeps
Action
Clear any accumulated result data. Useful for example to restart an average, or parameter statistics.
Description
View
Bool
Sets/Queries the trace's 'Viewed' state. When true, the trace is displayed on one of the display
graticules. Note that even when a trace is not visible, it may be used as a source for Math, Measure,
etc.
Description
ClearSweeps
Action
View
Bool
RESULT
app.SDA2.JitterMeasure.Parameters.ISI.Out.Result