Datadependentjitter – Teledyne LeCroy WavePro Automation Command User Manual
Page 582
Advertising

Automation Command and Query Reference Manual - Processor Reference
BitWidth
Integer
From 1 to 32 step 1
Range
Coeff
Double
From -1000 to 1000 step 1e-005
Range
Format
Enum
Values
Intel
Motorola
ID
BitPattern
MaxBits=29 NumBits=29 NumBytes=4 AllowedBitValues=01 PaddingChar=0
PadAlign=Left SizeAlign=BitFix Format=Ehex
Range
StartBit
Integer
From 0 to 63 step 1
Range
Term
Double
From -10000 to 10000 step 1e-005
Range
Type
Enum
Values
SignedInt
UnsignedInt
Units
String
Any number of characters
Range
DATADEPENDENTJITTER
app.Measure.Px.Operator (ParamEngine = "DataDependentJitter")
LevelType
Enum
Values
Absolute
Percent
LevelType
Enum
PercentLevel
Double
2-83
918501 RevA
Advertising