FirOrIir

Enum

Sets/Queries whether the filter Fx is an FIR filter or an IIR filter.

Description

Values

FIR

Finite Impulse Response Filter

IIR

Infinite Impulse Response Filter

FitAlways

Bool

LowFreqPass

Double

From 1000 to 1e+011 step 1

Range

Sets/Queries the lower cut-off frequency for the band-pass filter Fx.

Description

NumberOfTaps

Integer

From 3 to 2001 step 1

Range

Sets/Queries the number of taps in the filter Fx. Valid only when the AutoLength control is set to False.

Description

PassBandRipple

Double

From 0.5 to 20 step 0.1

Range

Sets/Queries the pass-band ripple.

Description

ReframeOutput

Bool

SampleRateText

String

Any number of characters

Range

StopBandAttenuation

Double

From 10 to 100 step 0.001

Range

Sets/Queries the stop-band attenuation of the filter Fx.

Description

TransitionWidth

Double

From 0 to 1e+011 step 1

Range

Sets/Queries the width of the transition in the frequency spectrum of filter Fx.

Description

FLOOR

app.Math.Fx.OperatorYSetup (Operator = "Floor")

Most negative or minimum values for an ensemble of sweeps, or "Floor"

2-20