Persistencetracesigma, Reframe – Teledyne LeCroy WavePro Automation Command User Manual

Page 542

Advertising
background image

Automation Command and Query Reference Manual - Processor Reference

ClearSweeps

Action

Clear any accumulated result data. Useful for example to restart an average, or parameter statistics.

Description

NumPoints

Integer

From 100 to 100000 step 1

Range

PctPopulation

Double

From 0.5 to 100 step 0.5

Range

ClearSweeps

Action

NumPoints

Integer

PctPopulation

Double

PERSISTENCETRACESIGMA

app.Math.Fx.OperatorYSetup (Operator = "PersistenceTraceSigma")

ClearSweeps

Action

Clear any accumulated result data. Useful for example to restart an average, or parameter statistics.

Description

NumPoints

Integer

From 100 to 100000 step 1

Range

Sigma

Double

From 0.5 to 10 step 0.1

Range

ClearSweeps

Action

NumPoints

Integer

Sigma

Double

REFRAME

app.Math.Fx.OperatorYSetup (Operator = "Reframe")

FitAlways

Bool

FitOnInpDefChanged

Bool

OneClickLarger

Bool

UseRegion

Enum

VerFrameStart

Double

VerFrameStop

Double

2-43

918501 RevA

Advertising