<2. Handling Cautions>

2-5

IM 01C27C01-01EN

Note 4. Battery Pack

USE ONLY BATTERY PACK YOKOGAWA

F9915MA OR F9915NS.

Note 5. Special Conditions for safe use

POTENTIAL ELECTROSTATIC CHARGING

HAZARD-SECURE DISTANCE OF 100MM

FROM ANTENNA.

DO NOT OPEN WHEN CL II, III, DIV 1,2

ATMOSPHERE IS PRESENT.

2.8.2 CSA Certification

Caution for CSA Intrinsically safe type. (Following

contents refer to “DOC No. ICS030”)
Note 1. Model EJX Series differential, gauge,

and absolute pressure transmitters with

optional code /CS17 are applicable for use

in hazardous locations

Certificate: 2325443

• Applicable standard: CAN/CSA-C22.2 No.0,

CAN/CSA-C22.2 No.0.4, C22.2 No.25,

CAN/CSA-C22.2 No.94,

CAN/CSA-C22.2 No.157, C22.2 No.213,

CAN/CSA-C22.2 No.61010-1,

CAN/CSA- C22.2 No.60079-0,

CAN/CSA-E60079-11, IEC60529

• Ex ia IIC T4

• Intrinsically Safe for Class I, Division 1,

Groups A, B, C & D, Class II, Division 1,

Groups E, F & G, Class III, Division 1

• Nonincendive for Class I, Division2,

Groups A, B, C & D, Class II, Division2,

Groups F & G, Class III, Division1

• Enclosure: IP66/IP67 and Type 4X

• Temperature Code: T4

• Ambient Temperature: –50 to 70°C

• Max. Process Temp.: 120°C

Note 2. Installation

• Installation should be in accordance with

Canadian Electrical Code Part I and Local

Electrical Code.

• Do not alter drawing without authorization

from CSA.

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation is prohibited and will void

Canadian Standards Intrinsically safe and

nonincendive Certification.

Transmitter

[Intrinsically Safe]

Group IIC, Zone 0

Class I, II, III, Division 1,

Groups A,B,C,D,E,F,G

[Nonincendive]

Class I, II, Division 2,

Groups A,B,C,D,F,G

Class III, Division 1

F0205.ai

Transmitter

[Intrinsically Safe]

Group IIC, Zone 0

Class I, II, III, Division 1,

Groups A,B,C,D,E,F,G

[Nonincendive]

Class I, II, Division 2,

Groups A,B,C,D,F,G

Class III, Division 1

Battery Pack

Antenna

(*1)

Arrester

(*1, *2)

*1: These apparatus are simple apparatus.

*2: Arrester may not be connected.

Antenna Connector

[Installation Diagram]

Amplifier housing code 7

Hazardous Area

Battery Pack

Amplifier housing code 8 and 9

Hazardous Area

Note 3. Battery Pack

• Use only YOKOGAWA battery pack

F9915MA or F9915NS.

Note 4. Special Conditions for safe use

• Potential electrostatic charging hazard -

secure distance of 100mm from antenna.

2.8.3 ATEX Certification

(1) Technical Data
Caution for ATEX Intrinsically safe type.
Note 1. Model EJX Series pressure transmitters

with optional code /KS27 for potentially

explosive atmospheres:

• No. KEMA 10ATEX0164 X

• Applicable Standard:

EN 60079-0:2009, EN 60079-11:2012,

EN 60079-26:2007

• Type of Protection and Marking code:

Ex ia IIC T4 Ga

• Group: II

• Category: 1 G

• Ambient Temperature: –50°C to 70°C

• Process Temperature (Tp.): 120°C max.

• Enclosure: IP66/IP67