Yokogawa EJX210B User Manual

Page 79

Advertising
background image

<10. Parameter Summary>

10-2

IM 01C27C01-01EN

Object

ID

Attribute

ID

Label

Description

Default

value

Handling

1.

UAPMO

block

(continued)

105

Power Supply

Status

Indicates the predicted battery level and the power

supply method.

0 = external power supply

1 = battery level 75% or more

2 = battery level 25% ~ 75%

3 = battery level 25% or less

R

106

EHType

*2

Available to write note into this parameter.

---

W

107

Power Supply

Voltage

*2

Indicates the measured power supply voltage (V).

---

R

110

Hardware Write

Protect

Allows recognizing the status of the hardware write

protection switch.

(Switch Off, Switch On)

R

111

Radio Silence

Repeats a cycle of a 1-hour pause and 6-minute

search if the instrument cannot join the network after a

time specified in Radio Silence has elapsed.

When 0 is set, the Radio Silence is invalid.

28800

W

112

Simulation Active

Alert

*2

The On/Off or priority for Simulation Active Alert can

be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

113

Soft Update

incomplete Alert

*2

The On/Off or priority for Soft Update incomplete Alert

can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

Not available for EJX.

1. TRUE

2. 15

W

114

Power low Alert

*2

The On/Off or priority for Power low Alert can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

115

Power Critical low

Alert

*2

The On/Off or priority for Power Critical low Alert can

be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

116

Fault prediction

Alert

*2

The On/Off or priority for Fault prediction Alert can be

set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

Not available for EJX.

1. TRUE

2. 15

W

117

Environmental

conditions Alert

*2

The On/Off or priority for Environmental conditions

Alert can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

118

Outside sensor

limits Alert

*2

The On/Off or priority for Outside sensor limits Alert

can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

119

Out of service

Alert

*2

The On/Off or priority for Out of service Alert can be

set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

120

Callibration

problem Alert

*2

The On/Off or priority for callibration problem Alert can

be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

Advertising