4 dimensions, Dimensions -12, General specifications – Yokogawa EJX210B User Manual

Page 99

Advertising
background image

<11. General Specifications>

11-12

IM 01C27C01-01EN

11.4 Dimensions

Flush type (Amplifier housing code 7)

No ring (Flushing connection ring code 0)

Extended type (Amplifier housing code 7)

With ring (Flushing connection ring code A, B, C, and D)

Unit: mm (approx. inch)

143 (5.63)

143 (5.63)

331

*3

(13.03)

91 (3.58)

91 (3.58)

181 (7.13)

21

1 (8.31)

21

1 (8.31)

331

*3

(13.03)

181 (7.13)

112 (4.41)

64

(2.52)

191 (7.52)

191 (7.52)

39

(1.54)

64

(2.52)

140

(5.51)

140

(5.51)

39

(1.54)

61

*4

(2.40)

61

*4

(2.40)

25

(0.98)

Ш

110 (4.33)

Ш

110 (4.33)

54

(2.13)

54

(2.13)

31

*2

(1.22)

24

(0.94)

24

(0.94)

41

(1.61)

41

(1.61)

67

(2.64)

67

(2.64)

Process flange

Process flange

Process connection

Process connector

(Optional)

Process connection

Process connector

(Optional)

Zero adjustment

Vent plug

Drain plug

Low pressure side

process connection

Vent plug

Drain plug

Low pressure side

process connection

31

*2

(1.22)

t

f

ØD

ØC

Øg

Ød

*1

n-Øh

n-Øh

Terminal side

Ground

terminal

143 (5.63)

331

*3

(13.03)

91 (3.58)

181 (7.13)

21

1 (8.31)

64

(2.52)

191 (7.52)

39

(1.54)

140

(5.51)

61

*4

(2.40)

25

(0.98)

Ø

110 (4.33)

54

(2.13)

31

*2

(1.22)

24

(0.94)

41

(1.61)

67

(2.64)

Process flange

X

2

Process connection

Process connector

(Optional)

Zero adjustment

Vent plug

Drain plug

Low pressure side

process connection

t

f

ØD

ØC

Øg

ØA

n-Øh

Integral indicator

Terminal side

Ground

terminal

Drain/vent plug

j

f

t

k

Ø

D

Ø

C

Ø

g

n-Øh

Zero adjustment

Flushing

connection

ring

*5

Terminal side

*5: Flushing connection ring

Flange size 3 or 2 inch

Spiral

gasket

Spiral

gasket

44

ø

Flange size 1 1/2 inch

Straight type

Reducer type

F03E.ai

Integral indicator

Integral indicator

Ground

terminal

A

B

*1: Indicates inside diameter of gasket contact surface.
*2: When option code K1 or K5 is selected, add 15 mm (0.59 inch) to the value in

the flange. Add 11 mm (0.36 inch) for drain/vent plugs of flushing connection ring.

*3: When amplifier housing code 8 is selected, the value is 390 mm (15.35 inch).

When amplifier housing code 9 is selected, the value is 270 mm (10.63 inch).

In both cases, the figures are shown as A or B accordingly.

*4: When amplifier housing code 8 or 9 is selected, add 1 mm (0.04 inch) to the value.

For electrical

connection code

5, 9, A, and D

6

(0.24)

76

(2.99)

Advertising