<10. Parameter Summary>

10-9

IM 01C27C01-01EN

Object

ID

Attribute

ID

Label

Description

Default

value

Handling

7.

AI3

block

(continued)

2

Block Mode

A universal parameter to indicate the block’s operation

status. O/S, Auto, and Man can be selected.

1. Target : Specify Al object mode.

2. Actual : Indicates current mode of Al object.

3. Permitted : Indicates the mode selected by Target

of Al object.

4. Normal : Indicate normal status mode of Al object.

1. Target =

Auto

2. Actual =

Auto

3. Permitted =

O/S+Auto

+Man

4. Normal =

Auto

W

3

Concentrator OID

Indicates the Concentrator object value that

corresponds to the data update of the PV value.

3

R

4

Scale

Allows specifying the upper or lower limit for the PV

scaling, unit code, etc.

1. EU at 100% : Indicate the upper limit of the PV

value.

2. EU at 0% : Indicate the lower limit of the PV value.

3. Units Index : Indicate the setting unit used for the

PV value.

4. Decimal : Indicate the digit number below the

decimal point displayed in the LCD indicator.

1. EU at 100%

= 100

2. EU at 0%

= 0

3. Units Index

= %

4. Decimal = 2

W

26

Tag Description

A universal parameter to store the comment that

describes the tag

AI3: Capsule

temperature

W

27

Process Value

Filter Time

Allows adjusting the time constant for filtering the PV

value.

Setting unit: Second. This is enabled for the

Continuous mode.

0 second

W

28

Simulate Switch

A simulation function switch for the AI object test

(Disable, Enable)

Disable

W

29

Transducer Value

When Simulate Switch is set to Disable, this value is

used as the input value for the AI object.

---

R

30

Simulate Value

When Simulate Switch is set to Enable, this value is

used as the input value for the AI object.

The input value can be changed.

---

W

53

Sensor Range

Parameter to nondimensionalize the sensor output

value.

K and deg C are selectable for the temperature unit.

1. EU at 100% : Indicates input value of the upper

limit.

2. EU at 0% : Indicates input value of the lower limit.

3. Units Index : Indicates the units of the

measurement range.

4. Decimal : Indicates the digit number below the

decimal point.

1. EU at 100%

= 130

2. EU at 0%

= -50

3. Units Index

= deg C

4. Decimal = 0

W

102

Tertiary Value

Select

Specifies either the capsule temperature or amplifier

temperature as the output value.

(CAP, AMP)

CAP

W

(Note) Handling: R=Read only, W=Read & Write

(Note) “Factory NAMUR category” refers to the four categories (C: Check function, M: Maintenance required, F: Failure, and O: Off

specification) according to NAMUR NE107*.

*1:

NAMUR NE107 “Self-Monitoring and Diagnosis of Field Devices”

*2: Applicable for Detachable antenna type (Amplifier housing code: 8 or 9).

*3: Applicable for amplifier housing code 7.

*4: Applicable for amplifier housing code 8 or 9.

*5: Minimum value is 1 second, when amplifier housing code 7 is specified.

*6: It is valid for not only continuous mode but also intermittent mode, when amplifier housing code 8 or 9 is specified.