3 optional specifications, Optional specifications -10, Optional specifications (others) – Yokogawa EJX210B User Manual

Page 97

Advertising
background image

<11. General Specifications>

11-10

IM 01C27C01-01EN

11.3 Optional Specifications

OPTIONAL SPECIFICATIONS (For Explosion Protected type)

Item

Description

Code

Factory Mutual (FM)

FM Intrinsically safe Approval

FS17

ATEX

ATEX Intrinsically safe Approval

KS27

Canadian Standards Association (CSA)

CSA Intrinsically safe Approval

CS17

IECEx

IECEx Intrinsically safe Approval

SS27

OPTIONAL SPECIFICATIONS (Others)

T07E.ai

Code

Description

Item

K1

Degrease cleansing treatment

Oil-prohibited use

D1

P calibration (psi unit)

Calibration units

*2

D3

bar calibration (bar unit)

(See table for Span and

Range Limits.)

D4

M calibration (kgf/cm

2

unit)

TF1

Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil.
Operation range: 20 to 150°C, 0 to 2 MPa (Not applicable for vacuum service).

Teflon film

*3 *4

A1

Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen permeation.

Gold-plated diaphragm

*5

Painting

Material
certificate

For Flush
type

P

Amplifier cover only

X2

Anti-corrosion coating *

1

M3W

High Pressure side: Process flange, Block, Ring

*6 *8

Low Pressure side: Cover flange

M4W

High Pressure side: Process flange, Block, Ring

*7 *8

Low Pressure side: Cover flange, Process connector

M0E

High Pressure side: Process flange, Block, Pipe, Base

*6

Low Pressure side: Cover flange

M1E

High Pressure side: Process flange, Block, Pipe, Base

*7

Low Pressure side: Cover flange, Process connector

For Extended
type

K5

Degrease cleansing and dehydrating treatment

Oil-prohibited use
with dehydrating treatment

(Flange rating)

(Test pressure)

Pressure test/Leak test
Certificate

*9*10

T51

JIS 10K

2 MPa (290 psi)

T54

JIS 20K

5 MPa (720 psi)

T52

ANSI/JPI Class 150

3 MPa (430 psi)

T56

ANSI/JPI Class 300

8 MPa (1160 psi)

*11

T55

ANSI/JPI Class 300

7 MPa (1000 psi)

*12

Nitrogen (N

2

) Gas

*13

Retention time: one minute

M0W

High Pressure side: Process flange, Block

*6

Low Pressure side: Cover flange

M1W

High Pressure side: Process flange, Block

*7

Low Pressure side: Cover flange, Process connector

Color change

Coating change

*1:

Not applicable with color change option.

*2:

The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option code

D1, D3, and

D4.

*3:

Applicable for flush type (process connection style code

W.)

*4:

Applicable for flushing connection ring code

0.

*5:

Applicable for wetted parts material code

SW, SE, WW, WE, and HW.Consult Yokogawa in case gold-plated diaphragm is required

for low pressure side.

*6:

Applicable for Low Pressure Side Process connection code

0 and 5.

*7:

Applicable for Low Pressure Side Process connection code

1, 2, 3, and 4.

*8:

Applicable for flushing connection ring code

A, B, C, and D.

*9:

The unit on the certificate is always MPa regardless of selection of option code

D1, D3, or D4.

*10: A flushing connection ring will not be applied when conducting the pressure test or leak test.

*11: Applicable for flush type (process connection style code

W.)

*12: Applicable for extended type (process connection style code

E.)

*13: Pure nitrogen gas is used for oil-prohibited use (option code

K1 and K5.)