Setting fru state alerts and actions – Brocade Network OS NETCONF Operations Guide v4.1.1 User Manual
Page 177

Network OS NETCONF Operations Guide
145
53-1003231-02
FRU monitoring
12
</threshold>
</fan>
<power>
<threshold>
<marginal-threshold>1</down-threshold>
<down-threshold>2</down-threshold>
</threshold>
</power>
<temp>
<threshold>
<marginal-threshold>1</down-threshold>
<down-threshold>2</down-threshold>
</threshold>
</temp>
<cid-card>
<threshold>
<marginal-threshold>1</down-threshold>
<down-threshold>0</down-threshold>
</threshold>
</cid-card>
<compact-flash>
<threshold>
<marginal-threshold>1</down-threshold>
<down-threshold>0</down-threshold>
</threshold>
</compact-flash>
<MM>
<threshold>
<marginal-threshold>1</down-threshold>
<down-threshold>0</down-threshold>
</threshold>
</MM>
<LineCard>
<threshold>
<marginal-threshold>1</down-threshold>
<down-threshold>0</down-threshold>
</threshold>
</LineCard>
<SFM>
<threshold>
<marginal-threshold>1</down-threshold>
<down-threshold>0</down-threshold>
</threshold>
</SFM>
</system-monitor>
</config>
</edit-config>
</rpc>
<rpc-reply message-id="1100" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<ok/>
</rpc-reply>
Setting FRU state alerts and actions
You can designate the action to be taken (send an e-mail message or issue a RASlog message)
when an FRU changes to a specific state. For example, you can configure the system to issue a
RASlog message when a line card is removed.