Measure:gating, Measure:source<x, Measure:fall – GW Instek GDS-3000 Series Programming Manual User Manual

Page 59

Advertising
background image

COMMAND DETAILS

59

:MEASure:GATing

Set

Query

Description

Sets or queries the measurement gating.

Syntax

:MEASure:GATing {OFF|SCREen|CURSor|?}

Parameter

OFF

Full record CURSor

Gating
between
cursors

SCREen

Gating set
to screen
width

Return parameter

Returns the gating. (OFF, SCREEN, CURSOR)

Example

:MEASure:GATing OFF

Turns gating off (full record).

:MEASure:SOURce<x>

Set

Query

Description

Sets or queries the measurement source for source1
or source2.

Syntax

:MEASure:SOURce<x> {CH1|CH2|CH3|CH4?}

Parameter

<x>

Source1 or
source2

CH1~CH4

Channel 1 to
4

1,2

Return parameter

Returns the source (CH1, CH2, CH3,CH4)

Example

:MEASure:SOURce1 CH1

Sets source1 to channel 1.

:MEASure:FALL

Query

Description

Returns the fall time measurement result.

Syntax

:MEASure:FALL{?}

Return parameter <NR3>

Chan Off

Indicates the source channel is not
activated.

Advertising