Running a fast sequence – GW Instek PEL-3000 Series User Manual User Manual
Page 119

OPERATION
117
Save
After all the steps for the sequence are
complete, press Save[F3] to save the steps.
Data Edit for Fast Sequences configuration is
complete.
Go to Timing Edit for Fast Sequences to edit the
sequence. Page 114.
Go to Running a Fast Sequence to run the fast
sequence. Page 117.
Running a Fast Sequence
Description
A Fast Sequence is run the same way as a
normal load.
Operation
1. Press
FUNC
> Sequence[F2] >
Fast Sequence[F2].
2. Turn fast sequence mode on by setting
F. Seq.[F1] to On.
FSEQ
will appear at the top of the display when
F. Seq. is On.
3. Turn the load on.
The fast sequence/chain starts immediately.
The
FSEQ
icon turns orange when the load is
turned on.
4. When a fast sequence is running, the screen
displays which step and loop is currently
active.
“Sequence Complete” will be shown on the
display at the end of the sequence.