Pel-3000 specifications, Rating (master / slave), Rating (booster / slave) – GW Instek PEL-3000 Series User Manual User Manual
Page 197

APPENDIX
195
PEL-3000 Specifications
The specifications apply when the PEL-3000 is powered on for at
least 30 minutes to warm-up to a temperature of 20˚C to 30˚C,
unless specified otherwise.
All specifications apply when using the rear panel terminals. If the
front panel terminals are used or if operating with long cables,
remote sense must be connected to the terminals.
In parallel mode: All operation/settings/resolution specifications
are xN. This does not include voltage settings and measured values.
The maximum slew rate settings also don’t change.
N = Number of units in parallel (same model)
N = 1 + 2 x Number of units in parallel (PEL-3211)
Rating (Master / Slave)
Model
PEL-3021
PEL-3041
PEL-3111
Operating Voltage
1.5V~150V
1.5V~150V
1.5V~150V
Current
35A
70A
210A
Power
175W
350W
1050W
Rating (Booster / Slave)
Model
PEL-3211
Operating Voltage
1.5V~150V
Current
420A
Power
2100W
Current Setting Accuracy
±(1.2% of set + 1.1% of f.s.)
M range applies to the full scale of H range.
Note: PEL-3211 only has H or M current ranges.