Cp mode – GW Instek PEL-3000 Series User Manual User Manual
Page 200

PEL-3000 User Manual
198
Setting Range
H Range
0V~157.5V
M Range
0V~15.75V
Resolution
H Range
10mV
M Range
1mV
Accuracy of Setting
*1
H, L Range
±(0.1 % of set + 0.1 % of f.s)
Input current variation
*2
12mV
*1 At the sensing point during remote sensing under the operating range of the
input voltage. It is also applied for the condition of the parallel operation.
*2 With respect to a change in the current of 10 % to 100 % of the rating at an
input voltage of 1.5 V (during remote sensing).
CP Mode
Model
PEL-3021
PEL-3041
PEL-3111
Operating Range
H Range
17.5W
~175W
35W~350W
105W
~1050W
M Range
1.75W
~17.5W
3.5W~35W
10.5W
~105W
L Range
0.175W
~1.75W
0.35W~3.5W
1.05W
~10.5W
Setting Range
H Range
0W~178.5W
0W~357W
0W~1071W
M Range
0W~17.85W
0W~35.7W
0W~107.1W
L Range
0W~1.785W
0W~3.57W
0W~10.71W
Resolution
H Range
10mW
10mW
100mW
M Range
1mW
1mW
10mW
L Range
0.1mW
0.1mW
1mW
Accuracy of Setting
*1
±(0.6 % of set + 1.4 % of f.s
*2
)
*1 It is not applied for the condition of the parallel operation.
*2 M range applies to the full scale of H range.