Resistance Accuracy of setting
H, M Range
±(0.5 % of set
*1
+ 0.5 % of f.s
*2
) + Vin
*3
/500 kΩ
L Range
±(0.5 % of set
*1
+ 0.5 % of f.s) + Vin
*3
/500 kΩ
*1
set = Vin / Rset
*2
f.s. = Full scale of High Range
*3
Vin = Input terminal voltage of Electronic Load
Power Operating Range
H Range
17.5W
~175W
35W~350W
105W
~1050W
M Range
1.75W
~17.5W
3.5W~35W
10.5W
~105W
L Range
0.175W
~1.75W
0.35W~3.5W
1.05W
~10.5W
Setting Range
H Range
0W~178.5W
0W~357W
0W~1071W
M Range
0W~17.85W
0W~35.7W
0W~107.1W
L Range
0W~1.785W
0W~3.57W
0W~10.71W
Resolution
H Range
10mW
10mW
100mW
M Range
1mW
1mW
10mW
L Range
0.1mW
0.1mW
1mW
Accuracy of Setting
*1
±(0.6 % of set + 1.4 % of f.s
*2
)
*1 It is not applied for the condition of the parallel operation.
*2 M range applies to the full scale of H range.
Soft Start
Operation Mode
CC, CR and CP
Selectable Time Range
1~ 200 ms/Res: 1ms
Time Accuracy
±(30%of set + 100us)
Remote Sensing
Voltage that can be Compensated
2V for a single line