3 connection diagram c520, Electrical connections – INOR IPAQ R520X User Manual

Page 16

Advertising
background image

4

ELECTRICAL CONNECTIONS

C520/C520X / R520/R520X

09/2010 • 86B5200001

www.inor.com

16

4.3 Connection diagram C520

ATTENTION!
To enable HART communication, the output circuit must have an output load of at least 250

Ω

.

ATTENTION!
C520 is a Category 3 equipment and the transmitter may not be operated in areas with

potentially explosive atmospheres other than Zone 2 and Division 2!

Figure 7: C520 connection

1

Voltage supply 10…36 VDC (terminals 6, 7)

2

Input

3

Output

4

Modem

5

SmartSense temperature sensor

6

Thermocouple

7

Pt100 3 wire connection

NOTE!
The HART modem is connected parallel to the output load or parallel to the output of the

transmitter (see Figure 7).

ATTENTION!
IPAQ C520 may be operated in areas with potentially explosive atmospheres (Zone 2 and Division

2) if the power supply has a protection ensuring that the power supply terminals of the

transmitter are limited to transients not exceeding 140% of the rated power supply.

1

2 3 4

5

1 2

3 4

5

6

5

5

7

2

1

3

4

4

USB

Advertising
This manual is related to the following products: