OPERATION

C520/C520X / R520/R520X

09/2010 • 86B5200001

www.inor.com

26

Figure 16: C520 in a multipoint connection (multi-drop mode) with up to 64 devices in parallel

1

Primary master

2

HART modem

3

Secondary master

4

Load

≥ 250 Ω

5

DC power supply

6

Terminal 6

7

Terminal 7

8

C520 or R520 loop current mode disabled up to 64 slaves can be connected

9

4 mA

10

HART

Figure 16 shows a multipoint connection (multi-drop) with up to 64 devices (C520/R520 or other

HART equipment) in parallel. The device's current outputs must be passive.

Burst mode is not supported.

5.2 Configuration of the C520/C520N/C520X / R520/R520N/R520X

ATTENTION!
Only an Ex approved HART modem located in safe area may be connected to a transmitter

placed in potentially explosive area.

In the table below are the factory settings of the C520/C520X / R520/R520X transmitters.

+