DEVICE DESCRIPTION

C520/C520X / R520/R520X

09/2010 • 86B5200001

www.inor.com

8

2

Device description

2.1 General description

The C520/C520X / R520/R520X are intelligent two-wire universal transmitters for measurement

with up to two user programmable channels in single, differential, average, minimum or

maximum mode.

The C520/C520X / R520/R520X are intended for:

• Temperature measurements with single or dual resistance thermometers
• Temperature measurements with single or dual thermocouples
• Temperature measurements with one resistance thermometers and one thermocouple
• Temperature difference measurements with resistance thermometers
• Measurements with potentiometers
• Voltage measurements in a range -10…1000 mV

To increase reliability and stability of the system, C520/R520 transmitters have dual sensor

inputs.

The dual sensor inputs enable new safety features such as sensor redundancy and sensor drift

monitoring.

C520S/C520XS/R520S/R520XS are reviewed by exida according to IEC 61508-2 for use in SIL 2

rated Safety Instrumented Systems (SIS). For safety instructions see the safety manual.

The C520 and R520 are the standard versions for use in safe (non-hazardous) areas.

The C520N and R520N are non-incendive versions for use in areas with potentially explosive

atmospheres, Zone 2 and Division 2.

The C520X and R520X are Intrinsically Safe versions for use in areas with potentially explosive

atmospheres, Zone 0, 1 and 2 and Division 1 and 2.

The C520, C520N and C520X are designed for installation in a B connection head according to

DIN 43729 or larger.

The R520, R520N and R520X are designed for installation on a top-hat rail according to

DIN 50022 / EN 60715.

The two-wire universal C520/C520X / R520/R520X transmitters are HART® 5 and 6-compatible.

Configuration of the C520/R520 transmitters is possible with:

• HART® 5 and 6 protocol via 4…20 mA output circuit
• HART® 5 and 6 handheld terminal
• The graphic user interface DTM
• The third part PC software with a FSK modem for HART® 5 and 6 communication
• PC configuration software ConSoft with PC Configuration Kit - ICON

The PC configuration software ConSoft is used for configuration, display and documentation.

The current ConSoft version is available for downloading on our website www.inor.com.