PLC logic for NORD SK 54xE frequency inverters

34

BU 0550 GB-0813

3.2.4.6

ROL

Bit-wise left rotation of the accumulator. Here, the content of the accumulator is shifted n times to the left,
whereby the left Bit is reinserted on the right.

BOOL

BYTE

INT

DINT

Possible data types

X

X

X

Commands

Explanation

LD 175

Loads the value 1010_1111

ROL 2

The contents of the accumulator are rotated 2x to the
left

ST Value1

Saves the value 1011_1110 in Value1

Table 33 ROL

3.2.4.7

ROR

Bit-wise right rotation of the accumulator. Here, the content of the accumulator is shifted n times to the right,
whereby the left Bit is reinserted on the left.

BOOL

BYTE

INT

DINT

Possible data types

X

X

X

Commands

Explanation

LD 175

Loads the value 1010_1111

ROR 2

The contents of the accumulator are rotated 2x to the
right

ST Value1

Saves the value 1110_1011 in Value1

Table 34 ROR

3.2.4.8

SHL

Bit-wise left shift of the accumulator. Here, the contents of the accumulator are shifted n times to the left.
The bits which are pushed out are lost.

BOOL

BYTE

INT

DINT

Possible data types

X

X

X

Commands

Explanation

LD 175

Loads the value 1010_1111

SHL 2

The contents of the accumulator are shifted 2x to the
left

ST Value1

Saves the value 1011_1100 in Value1

Table 35 SHL