3 AWL (Instruction List, IL)

BU 0550 GB-0813

61

3.5.3.2

FB_Gearing

The position and speed of the frequency inverter can be synchronised to that of a master inverter via the
function module FB_Gearing. The slave which used this function always follows the movements of the
master inverter.

The synchronisation is always absolute, i.e. the position of the slave and the master are always the same.

NOTE

If the slave is switched into gear mode when it is in a different position to the master, it then
moves to the master position at maximum frequency.

If a gear ratio is specified, this also results in a new position when switched on again.

The position value to which synchronisation is carried out, as well as the speed, must be communicated via
the Broadcast channel.

The function is activated via the ENABLE input; for this, the position control must be activated and the
output stage enabled. The output stage can be enabled e.g. with the function MC_Power. If ENABLE is set
to 0, the frequency inverter brakes to 0Hz and stops. The inverter is now once again in position control
mode.

If MC_Stop is activated, the frequency inverter exists from gear mode and the ABORT output is set to 1. In
case of errors in the FB, ERROR is set to 1 and the cause of the error is shown in ERRORID. ERROR,
ERRORID and ABORT can be reset by setting ENABLE to 0.

Table 87 FB_Gearing

Gear ratios or a change of direction of rotation can be set via the parameters P607[-05] or P608[-05] Further
details can be found in Manual BU0510 (Supplementary manual for POSICON position control).

3.5.3.3

FB_FlyingSaw

The Flying Saw function is an extension of the gear function. With the aid of this function it is possible to
synchronize a running drive unit to a precise position. In contrast to FB_Gearing, synchronisation is relative,
i.e. the slave axis moves synchronously to the position of the master which applied at the start of the "Flying
Saw" The synchronisation process is illustrated in the figure below.

VAR_INPUT

VAR_OUTPUT

Input

Explanation

Type

Output

Explanation

Type

ENABLE

Synchronous running active

BOOL

VALID

Gear unit function is active

BOOL

ABORT

Command aborted

BOOL

ERROR

Error in FB

BOOL

ERRORID

Error code

INT

ERRORID

Explanation

0

No error

1000h

FI is not enabled

1200h

Position control not activated

1201h

The PLC setpoint position High is not parameterised

1202h

The PLC setpoint position Low is not parameterised