2 process values, 1 inputs and outputs, Inputs and outputs – NORD Drivesystems BU0550 User Manual

Page 87

Advertising
background image

4 Frequency inverter details

BU 0550 GB-0813

87

4.2 Process values

All analog and digital inputs and outputs or bus setpoints and actual values can be read and processed by
the PLC or can be set by the PLC (if they are output values. Access to the individual values is by means of
the process values listed below.

For all output values, the output (e.g. digital outputs or PLC setpoint) must be programmed so that the PLC
is the source of the event.

All process data is read in from the PLC by the FI at the start of each cycle and is only written to the
frequency inverter at the end of the program.

The following table lists all of the values which can be directly accessed by the PLC. All other process
values must be accessed via the function blocks MC_Readparameter or MC_WriteParameter.

4.2.1

Inputs and outputs

Here, all process values which describe the I/O interface of the frequency inverter are listed.

Index Name

Function

Standardisation

Type

Access

0

_0_Set_digital_output

Set digital outputs

Bit 0: MFR1

Bit 1: MFR2

Bit 2: Dout1

Bit 3: Dout2

Bit 4: dig. funct. Aout

Bit 5: Dout3 (Din7)

Bit 6: Bus status word Bit 8

Bit 7: Status word Bit 9

Bit 8: BusIO Bit1

Bit 9: BusIO Bit2

Bit 10: BusIO Bit3

Bit 11: BusIO Bit4

Bit 12: BusIO Bit5

Bit 13: BusIO Bit6

Bit 14: BusIO Bit7

Bit 15: BusIO Bit8

INT

R/W

1

_1_Set_analog_output

Set analog output FI

10.0V = 100

BYTE

R/W

2

_2_Set_external_analog_out1 Set analog output 1 IOE

10.0V = 100

BYTE

R/W

3

_3_Set_external_analog_out2 Set analog output 2 IOE

10.0V = 100

BYTE

R/W

4

_4_State_digital_output

State of digital outputs

Bit 0: MFR1

Bit 1: MFR2

Bit 2: Dout1

Bit 3: Dout2

Bit 4: dig. funct. Aout

Bit 5: Dout3 (Din7)

Bit 6: Bus status word Bit 8

Bit 7: Status word Bit 9

Bit 8: BusIO Bit1

Bit 9: BusIO Bit2

Bit 10: BusIO Bit3

Bit 11: BusIO Bit4

Bit 12: BusIO Bit5

Bit 13: BusIO Bit6

Bit 14: BusIO Bit7

Bit 15: BusIO Bit8

INT

R

5

_5_Digital_input

State of digital inputs

Bit 0: DIN1

Bit 1: DIN2

Bit 2: DIN3

Bit 3: DIN4

Bit 4: DIN5

Bit 5: DIN6

Bit 6: DIN7

Bit 7: Digital function AIN1

Bit 8: Digital function AIN2

INT

R