4 Frequency inverter details

BU 0550 GB-0813

89

Index Name

Function

Standardisation

Type

Access

34

_34_PLC_Busmaster_Control_word

Master function con-
trol word (bus master
function) via PLC

Corresponds to USS profile

INT

R/W

35

_35_PLC_32Bit_set_val1

32Bit PLC setpoint

- P553[1] = Low

word

of

the 32Bit value

- P553[2] = High

word

of the 32Bit value

_

DINT

R/W

36

_36_PLC_32Bit_act_val1

32Bit PLC actual val-
ue

- PLC actual value 1 =
Low

word

of the 32Bit

value

- PLC actual value 2 =
High

word

of the 32Bit

value

_

DINT

R/W

Table 105 Process values for PLC setpoints and actual values

4.2.3

Bus setpoints and actual values

These process values reflect all setpoints and actual values which are transferred to the frequency inverter
via the various bus systems.

Index Name

Function

Standardisation

Type

Access

40

_40_Inverter_status

FI Status word

Corresponds to
USS profile

INT

R

41

_41_Inverter_act_val1

FI Actual value 1

100% = 4000h

INT

R

42

_42_Inverter_act_val2

FI Actual value 2

100% = 4000h

INT

R

43

_43_Inverter_act_val3

FI Actual value 3

100% = 4000h

INT

R

44

_44_Inverter_act_val4

FI Actual value 4

100% = 4000h

INT

R

45

_45_Inverter_act_val5

FI Actual value 5

100% = 4000h

INT

R

46

_46_Inverter_lead_val1

Broadcast Master Function: Master
value 1

100% = 4000h

INT

R

47

_47_Inverter_lead_val2

Broadcast Master Function: Master
value 2

100% = 4000h

INT

R

48

_48_Inverter_lead_val3

Broadcast Master Function: Master
value 3

100% = 4000h

INT

R

49

_49_Inverter_lead_val4

Broadcast Master Function: Master
value 4

100% = 4000h

INT

R

50

_50_Inverter_lead_val5

Broadcast Master Function: Master
value 5

100% = 4000h

INT

R

51

_51_Inverter_control_word

Resulting bus control word

Corresponds to
USS profile

INT

R

52

_52_Inverter_set_val1

Resulting main bus setpoint 1

100% = 4000h

INT

R

53

_53_Inverter_set_val2

Resulting main bus setpoint 2

100% = 4000h

INT

R

54

_54_Inverter_set_val3

Resulting main bus setpoint 3

100% = 4000h

INT

R

55

_55_Inverter_set_val4

Resulting main bus setpoint 4

100% = 4000h

INT

R

56

_56_Inverter_set_val5

Resulting main bus setpoint 5

100% = 4000h

INT

R

57

_57_Broadcast_set_val1

Broadcast Slave: Auxiliary setpoint 1

100% = 4000h

INT

R

58

_58_Broadcast_set_val2

Broadcast Slave: Auxiliary setpoint 2

100% = 4000h

INT

R

59

_59_Broadcast_set_val3

Broadcast Slave: Auxiliary setpoint 3

100% = 4000h

INT

R

60

_60_Broadcast_set_val4

Broadcast Slave: Auxiliary setpoint 4

100% = 4000h

INT

R

61

_61_Broadcast_set_val5

Broadcast Slave: Auxiliary setpoint 5

100% = 4000h

INT

R