4 Frequency inverter details

BU 0550 GB-0813

81

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P420

… [-01]

… [-10]

Digital inputs

(Digital input functions)

0 … 80

[-01] = { 1 }

[-02] = { 2 }

[-03] = { 8 }

[-04] = { 4 }

all others = { 0 }

Up to 10 freely programmable digital inputs are available in the SK 54xE. Execution of the
PLC program can be stopped with the settings listed below.

[-01] = Digital input 1 (DIN1), Enable right as factory setting,

control terminal 21

[-02] = Digital input 2 (DIN2), Enable left as factory setting,

control terminal 22

[-03] = Digital input 3 (DIN3), Parameter set changeover Bit 0 as factory setting,

control terminal 23

[-04] = Digital input 4 (DIN4), Fixed frequency 1 as factory setting,

control terminal 24

[-05] = Digital input 5 (DIN5), no function as factory setting,

control terminal 25 (only available in devices size 5 and above)

[-06] = Digital input 6 (DIN6), no function as factory setting,

control terminal 26

[-07] = Digital input 7 (DIN7), no function as factory setting,

control terminal 27, (DIN7 can also be used as DOUT3)

[-08] = Digital function Analog1 (AIN1), no function as factory setting,

control terminal 14, (Digital function Analog input AIN1)

[-09] = Digital function Analog2 (AIN2), no function as factory setting,

control terminal 16, (Digital function Analog input AIN2)

[-10] = Digital input 8 (DIN8), no function as factory setting,

control terminal 7, (DIN8 can also be used as DOUT2)

Setting:

80 = PLC Stop: Execution of the PLC program is stopped as long as the signal is present.

P434

… [-01]

… [-05]

Digital output function

(Digital output functions)

P

0 … 40

[-01] = { 1 }

[-02] = { 7 }

all others = { 0 }

The digital outputs can be set by the PLC via the PLC setting.

[-01] = Binary output 1 / (MFR1), external brake as factory setting,

control terminals 1/2

[-02] = Binary output 2 / (MFR2), Error as factory setting,

control terminals 3/4

[-03] = Binary output 3 / (DOUT1), no function as factory setting,

control terminal 5

[-04] = Binary output. 4 / (DOUT2), no function as factory setting,

control terminal 7

[-05] = Binary output 5 / (DOUT3), no function as factory setting,

control terminal 27, (DOUT3 can also be used as DIN7)

Setting:

40 = Output via PLC: The output is set by the PLC