Discovery from hp sim discovery from hp se – HP Storage Essentials NAS Manager Software User Manual

Page 102

Advertising
background image

Discovering NAS Devices, Tape Libraries, Switches and Storage Systems

70

for the server running HiCommand Device Manager. Do not point to the disk array for the storage

system.
To obtain information about HDS storage systems, the management server must be able to access

the port HiCommand Device Manager uses to listen. By default, HiCommand Device Manager

listens on port 2001, and the management server assumes this configuration at discovery time. If

HiCommand Device Manager uses a different port, specify this other port when you discover

HiCommand Device Manager.
Keep in mind the following:

You cannot scan an IP range to discover an instance of HiCommand Device Manager that

listens on a port other than 2001. The management server does not allow port numbers in the

scanning of IP ranges, and thus, you are not able to specify the port.

The management server communicates with HiCommand Device Manager through a nonsecure

connection. If you want the management server to communicate with HiCommand Device

Manager through a secure sockets layer (SSL) connection, you must modify an internal property

or use HTTPS when you discover HiCommand Device Manager. See

Communicating with

HiCommand Device Manager Over SSL

” on page 689.

Discovery from HP SIM
To discover an HDS storage system that listens on a port other than 2001, you must provide the

following information to HP System Insight Manager:

IMPORTANT:

First discover the IP address of the server running HiCommand Device Manager. See

Adding an IP Range for Scanning

” on page 27 or ”

Adding a Single IP Address or DNS Name for

Discovery

” on page 28 for more information. Then, select Options > Protocol Settings >

System Protocol Settings

and select the host you discovered as a target. On the System Protocol

Settings page, provide the port number for the server under the WBEM section. You can also

provide the user name and password for the element on this page if the user name and password

are not one of the defaults.

The name of the server and the port HiCommand Device Manager uses to listen. Enter its port

number on the System Protocol Settings page (Options > Protocol Settings > System
Protocol Settings

) under the WBEM section. Refer to the HP SIM documentation for more

information.

User name for HiCommand Device Manager.

Password for HiCommand Device Manager.

NOTE:

Adding new ports or interop namespaces cause the discovery process to take longer

because HP Systems Insight Manager tries all possible combinations of ports, interop namespaces,

and user name/password pairs on each IP address in the discovery range.

Discovery from HP SE
To discover an HDS storage system that listens on a port other than 2001:

Advertising