HP Storage Essentials NAS Manager Software User Manual

Page 726

Advertising
background image

Troubleshooting

694

AIX host

using an

IBM

Storage

System

NA

If you have an AIX host using an IBM storage system, not all bindings

may be displayed on the bindings page on the Navigation tab. For

example, assume diskA on host123 has six paths. All six bindings

may not be displayed.

Hosts

running SGI

IRIX version

6.5.22 or

6.5.24

NA

If a host running SGI IRIX version 6.5.22 or 6.5.24, the HBA port

page on the Navigation tab in System Manager displays 0 GB/s for

HBA ports.

SGI IRIX

host

CXFS file

systems

The management server can only monitor CXFS file systems from the

host generating the input/output. For example, assume the elements

are part of a CXFS file system. When you generate input/out into the

metadata server into /folder, only the metadata server is able to

monitor the file system. For example, assume the metadata server

generates 100 KB write, the management server displays 0 KB write

for /folder on the metadata client.
See ”

About the Data from CXFS File Systems

” on page 335 for more

information.

Solaris host Sun SAN

Foundation

Suite driver

(Leadville

driver)

The bindings page reports a SCSI number that comes from the

HBAAPI. This number cannot be seen by the user. For example SCSI

target 267008 does not correlate to anything.

Table 146

Known Device Issues (continued)