Parameters, Comments, Common operation tags – HP StorageWorks XP Remote Web Console Software User Manual

Page 150: Serialnumber tag, 150 comments, 150 common operation tags, Parameters of the serialnumber tag

Advertising
background image

In this case, you need to prepare multiple spreadsheets. For details, see the documentation for
program products that support the CFL Extension.

Parameters

You can specify the configuration of the storage system as a parameter. Each parameter must be
separated with a comma ( , ). Asemicolon ( ; ) is required at the end of the line where a parameter
is written. Note that a comma is required as separator before the semicolon.

An example of writing a parameter is as follow:

[SerialNumber}

65536,;

Parameters might be written in a hierarchy structure for a certain program product. The identifier (+)
is required at the beginning of a line, and must appear in the following order:

+

+,+

+,+,+

The actual parameters depend on the program products. For detailed information about parameters,
see the documentation for program products that support the CFL Extension.

Comments

You can also type comments in a spreadsheet. Comments can consist of any characters in any
language.

The line that begins with the # character, or includes only a linefeed code, is recognized as a comment.
Do not insert any space or character before the # character.

Common Operation Tags

Operation tags are divided into two types: common operation tags for all program products and
program product-specific operation tags. For program product-specific operation tags, see the
documentation for program products that support the CFL Extension.

SerialNumber Tag

The SerialNumber tag, which is a common operation tag, allows you to verify that the serial number
in the spreadsheet matches the serial number of the storage system. It is recommended that you write
the SerialNumber tag to prevent possible misuses of spreadsheets.

Table 25 Parameters of the SerialNumber Tag

Number of Charac-
ters

Range of Values

Setting

Parameter

Columns in the
Spreadsheet

5 decimal digits or less

00000 to 99999

Serial number of the
storage system.

SerialNumber

A

Using the CFL Extension

150