Representation in vmware vsphere, see, Table 6-11 – HP XP7 Storage User Manual

Page 137

Advertising
background image

Displayed Item

Description

No

summary

displayed

Summary

displayed

Vendor ID: The name of the storage system vendor.

Product ID: Indicates the storage system product ID,

emulation type, or model ID.
For more details, see

Table 6-12 Product ID displayed

by the view -path operation on page 6-46

.

Serial number: The serial number of the storage

system.

If an HAM environment is not used, a hyphen (-) is

displayed.

Org-iLU

-

For HAM environments, an LU number on the secondary

volume (S-VOL) is displayed.

For HUS VM, indicated by a hexadecimal number. The

first two characters of iLU are the CU number, and the

last two characters are the internal LU number within

the CU.

For Hitachi Virtual Storage Platform, indicated by a

hexadecimal number. The first two characters of iLU

are the number of the logical DKC (Disk Controller), the

middle two numbers are the CU number, and the last

two characters are the internal LU number within the

CU.

If an HAM environment is not used, a hyphen (-) is

displayed.

Legend:

- : Not displayed

#1

The path information is displayed only when a value is specified for the -
path -item parameter.

#2

This storage system applies when the dynamic I/O path control function is

disabled.

Table 6-11 Elements of a path name

Element

VMware vSphere representation

Host port number (example: 0000)

Host ID (host port number)

Bus number (example: 0000)

Channel number (bus number)

Target ID (example: 000000000000003A)

Target ID

Host LU number(example: 0005)

Lun (host LU number)

Command Reference

6-45

Hitachi Dynamic Link Manager (for VMware®) User Guide